![ABB Robotics IRB 6790 Скачать руководство пользователя страница 498](http://html1.mh-extra.com/html/abb-robotics/irb-6790/irb-6790_product-manual_450837498.webp)
Note
Action
xx1300000484
Refit the cable bracket.
10
See
Performing a leak-down test on
Perform a leak-down test.
11
Disconnect the 24 V DC power supply.
12
xx1200001084
Reconnect the connectors.
13
Gasket: 3HAC033489-002
xx1200001095
Check the gasket.
Replace if damaged.
14
Continues on next page
498
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.7.6 Replacing the axis-6 motor
Continued