![ABB Robotics IRB 6790 Скачать руководство пользователя страница 475](http://html1.mh-extra.com/html/abb-robotics/irb-6790/irb-6790_product-manual_450837475.webp)
Note
Action
CAUTION
Turn off the air pressure supply.
6
Retrieving access to the wrist cabling
Use this procedure to remove the wrist cover to retrieve access to the axis-5 and
axis-6 motor cables.
Note
Action
DANGER
Make sure that all supplies for electrical
power and hydraulic pressure are turned
off.
1
xx1300002247
Remove the wrist cover.
2
xx1500001030
Remove the heat protection plates from the
motor with the cabling still attached to the
plate.
3
Continues on next page
Product manual - IRB 6790
475
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.7.5 Replacing the axis-5 motor
Continued