Preparations before removing the cable harness in the base
Note
Action
DANGER
Make sure that all supplies for electrical
power and hydraulic pressure are turned
off.
1
CAUTION
Turn off the air pressure supply.
2
xx1700001580
Remove the base cover.
3
xx1700001584
Remove the metal clamp inside the base.
4
xx1700002245
Disconnect the balancing device air hose
inside the base.
5
Continues on next page
Product manual - IRB 6790
513
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.8.1 Replacing the axis-1 gearbox
Continued