Preparations before removing the cable harness
Note
Action
xx1200001081
Jog the robot to the specified position:
•
Axis 1: 0°
•
Axis 2: -60°
•
Axis 3: +60°
•
Axis 4: 0°
•
Axis 5: +90°
•
Axis 6: No significance.
Note
The specified position is a recommended
position.
Axis-5 must be oriented as close as pos-
sible to +90° to be able to open the axis-6
motor cover and to remove the axis-6 motor
cables, and in order to avoid the spiral of
the cable harness in the carrier, being un-
wound or placed in the wrong position.
Depending on what tool is used, the other
axes may need to be jogged to another
position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
to the robot, before entering the safe-
guarded space.
2
xx1700001593
Check the leak flow value on the flow
sensor.
Note the value to be able to compare it
when repair is completed.
3
CAUTION
Turn off the air pressure supply.
4
Continues on next page
188
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued
Содержание IRB 6790
Страница 1: ...ROBOTICS Product manual IRB 6790 ...
Страница 2: ...Trace back information Workspace 20A version a8 Checked in 2020 03 09 Skribenta version 5 3 033 ...
Страница 8: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 38: ...This page is intentionally left blank ...
Страница 164: ...This page is intentionally left blank ...
Страница 612: ...This page is intentionally left blank ...
Страница 638: ...This page is intentionally left blank ...
Страница 644: ...This page is intentionally left blank ...
Страница 658: ...This page is intentionally left blank ...
Страница 660: ...This page is intentionally left blank ...
Страница 667: ......