Note
Action
xx1200001016
Refit the cable gland cover by performing
the following steps:
•
Slide the cable gland cover onto the
inner screw.
•
Refit and tighten the outer screw.
•
Tighten the inner screw. Make sure
that the gasket is not damaged.
Note
Replace the gasket if damaged.
2
xx1200001015
Connect the connectors.
Connect in accordance with the markings
on the connectors.
3
O-ring, axis 5: 3HAC067744-001.
xx1200001021
Make sure the o-ring on the motor is undam-
aged.
Replace if damaged.
4
CAUTION
When fitting the motor cover, make sure
that none of the cables inside will be dam-
aged.
5
Continues on next page
282
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm