Disconnecting the air hoses, CP/CS cabling and Ethernet cabling (if equipped)
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800002500
Disconnect the air hoses from the Y-shaped con-
nectors.
2
xx1800002501
Disconnect the connectors.
•
J2.C1
•
J2.C2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Tip
The connector clip has to be pressed (1) and
pushed forward (2) to separate the J2.C2 (for
Ethernet cabling).
xx1800002943
3
Continues on next page
Product manual - IRB 1100
467
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.8.1 Replacing the axis-1 gearbox
Continued