Note
Action
xx1900000008
Remove the adjustment screw from the motor.
10
Reconnecting the axis-5 motor connectors
Note
Action
xx1800003025
Reconnect the connectors.
•
FB5
•
MP5
Tip
See the number markings on the connectors for
help to find the corresponding connector.
1
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Insert the cabling and connectors into the wrist.
3
Refitting the wrist cover
Note
Action
Apply grease to the cable package, cover all
moving area of the package.
1
Apply grease to the cover that has contacting area
with the cable package.
2
Continues on next page
Product manual - IRB 1100
447
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.7.5 Replacing the axis-5 motor
Continued
Содержание IRB 1100
Страница 1: ...ROBOTICS Product manual IRB 1100 ...
Страница 2: ...Trace back information Workspace 20B version a15 Checked in 2020 06 01 Skribenta version 5 3 033 ...
Страница 8: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 588: ...This page is intentionally left blank ...
Страница 610: ...This page is intentionally left blank ...
Страница 614: ......
Страница 615: ......