Note
Action
xx1900000008
Install an M4x25 or longer adjustment screw to
the motor.
Note
Do not insert the entire screw to the hole.
5
Initial referenced force for used
belt: 13.58-14.84 N (for reference
only)
Use a handheld tensiometer hooking to the screw
and pull the tensiometer to reach the initial refer-
enced force.
6
Initial referenced force for new belt:
19.4-21.2 N
xx1900000027
Tightening torque: 1.4 Nm
xx1800003290
Secure the motor with the screws.
7
Used belt: 151-162 Hz
Use an acoustic tensiometer to measure the tim-
ing belt tension.
8
New belt: 167-213 Hz (for reference
only)
If the timing belt tension does not meet the require-
ment, loosen the motor screws and readjust.
9
Continues on next page