Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 46
2
xx1800002467
Remove the SMB cover attachment screws and
carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
There are cabling attached to the cover. The
cover cannot be removed completely until the
connectors are removed.
3
xx1800002468
Disconnect the connectors.
•
SMB.P7
•
SMB.J1
•
SMB.J2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
4
Remove the SMB cover completely from the base.
5
Removing the battery pack
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 46
2
Continues on next page
Product manual - IRB 1100
189
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the SMB unit
Continued
Содержание IRB 1100
Страница 1: ...ROBOTICS Product manual IRB 1100 ...
Страница 2: ...Trace back information Workspace 20B version a15 Checked in 2020 06 01 Skribenta version 5 3 033 ...
Страница 8: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 588: ...This page is intentionally left blank ...
Страница 610: ...This page is intentionally left blank ...
Страница 614: ......
Страница 615: ......