FB: Communication Parameters ( total 6 )
Code
Name
Setting Scope
Min
Unit
Defaulted
Value
Address Change
PB.00
Communication
configuration
LED Units: Baud
rate selection
0: 1200bps
1: 2400bps
2: 4800bps
3: 9600bps
4: 19200bps
5: 38400bps
1
4
B00H
×
PB.00
Communication
configuration
LED Tens: Data
format
0: 1-8-2-N
format, RTU
1: 1-8-1-E
format, RTU
2: 1-8-1-O
format, RTU
LED Hundreds:
Virtual input
terminals
0: Invalid
1: Valid
1
4
B00H
×
PB.01
Local address
0
~
247, 0 is
broadcast
address
1
1
B01H
×
PB.02
Communica-tion
timeout detect
0.0
~
1000s
Don't inspect is
beyond time at 0
0.1
0.0s
B02H
×
PB.03
Response delay
0
~
1000ms
1
5ms
B03H
×
PB.04
Master-slave
selection
0: Slave
machine
1: Master
machine
1
0
B04H
×
PB.05
Ratio of slave
inverter setting
frequency
0.0~10.00
0.01
1.00
B05H
×