F1 GROUP: Motor Parameter ( total 11 items )
Code
Name
Setting Scope
Min
Unit
Defaulted
Value
Address
Change
P1.07
Rotor
resistance
0.0
~
50.00%
0.01%
Power
determination
107H
○
P1.08
Mutual
inductance
0.0
~
2000.00%
0.1%
Power
determination
108H
○
P1.09
Rated slip
frequency
0.00
~
20.00Hz
0.01Hz
0Hz
109H
○
P1.10
Auto
tuning
0: Auto tuning
disable
1: Stationary
auto tuning
2: Rotating
auto tuning
1
0
10AH
×
F2 Group: Start/Stop Parameter ( Total 15 items )
Code
Name
Setting Scope
Min
Unit
Defaulted
Value
Address
Change
P2.00
Reserved
-
-
-
200H
*
P2.01
Start
frequency
0.20
~
60.00Hz
0.01Hz
0.5Hz
201H
○
P2.02
Start
frequency
hold time
0.0
~
10.0s
0.1s
0.0s
202H
○
P2.03~
P2.07
Reserved
-
-
-
203H~
207H
*
P2.08
Stop
modes
0: Decelerate to
stop
1: Coast to stop
2: Decele
DC braking
1
0
208H
×
P2.09
Frequency
threshold
of DC
braking
0.00
~
60.00Hz
0.01Hz
1.00Hz
209H
○