P9.30=0, not auto restart.
In fact, whether to auto restart depends on P9.30, inverter state at power
failure and control mode. Refer to Table 7-13.
Table 7-13 Conditions of Restart after Power-on
P9.30
State
before
power off
Control mode at power-on
Keypad
Serial
port
3-wire terminal 1,
2
2-wire terminal 1,
2
None
None
None
None
Yes
0
Stop
0
0
0
0
0
Run
0
0
0
0
0
1
Stop
0
0
0
0
1
Run
1
1
1
0
1
Note
:
1
.
Table 7-13
shows the inverter action under different conditions. “0” means the
inverter is ready to start, and “1” means auto start.
2
.
When the control mode is keypad or serial port or 3-wire terminal 1 and 2, there
is no RUN command at power on.
3
.
If there is a Stop command, the inverter will not start.
P9.31~P9.33 Reserved
Reserved
P9.34 Terminal filter time
Range: 0.5~100.0ms
【
7.5ms
】
P9.35 Current count value
Range: 0~65535
【
0
】
Terminal filter time: can increase P9.34 properly, improve the
anti-interference ability of the X input terminals. Terminal filter, the longer
terminal action delay time is longer.
The current count value: built-in counter for input pulse count, the value
can be modified on-line, this value can be saved when power off.
P9.30 Conditions of restart after
power failure
Range: 0, 1
【
0
】
P9.36 Under-voltage point set
Range: 75.0%
~
135.0%
【
90%
】
P9.37~P9.42 Reserved
Reserved
P9.43 PWM Model optimization
Range: 0000
~
0211H
【
0011
】