A-TS
60
https://a-ts.cn/en/
Motor temperature rise
↑
↓
Inverter temperature rise
↓
↑
Leakage current
↓
↑
Interference to external
↓
↑
Output current wave
Worse
Better
0: Disabled
1: Enabled
When CWF auto adjustment is enabled, the inverter can adjust CWF
automatically according to the temperature inside the inverter.
JogFrequency: frequency in Jog mode
Jog acceleration/deceleration time: Acc/Dec time in Jog mode
Thou
Hun
Ten
One
BIT0:
Positive or negative logic of X1
BIT1:
Positive or negative logic of X2
BIT2:
Positive or negative logic of X3
BIT3:
Positive or negative logic of X4
BIT0:
Positive or negative logic of X5
BIT1:
Reserved
BIT2:
Reserved
BIT3:
Reserved
BIT0:
Reserved
BIT1:
Reserved
BIT2:
Positive or negative logic of Y1
BIT3:
Reserved
BIT0:
Reserved
BIT1:
Reserved
BIT2:
Reserved
BIT3:
Reserved
Figure 7-16 Positive or Negative logic of Terminals
P9.03 CWF auto adjustment
Range: 0, 1
【
0
】
P9.04 Reserved
Reserved
P9.05 Jog frequency
Range: 0.10
~
P0.07Hz
【
5.00Hz
】
P9.06 Reserved
Reserved
P9.07 Jog Acc time
Range: 0.1
~
60.0s
【
6.0s
】
P9.08 Jog Dec time
Range: 0.1
~
60.0s
【
6.0s
】
P9.09~ P9.14 Reserved
Reserved
P9.15 Positive or negative logic of terminal
Range: 000
~
FFFH
【
000H
】