shielding layer is reliably grounded.
Never connect the braking resistor between the DC bus terminals
( + ) and ( - ) , or it may cause a fire !
Before power-on:
DANGER
Make sure the following requirements, failure to comply will cause
damage to the inverter.
– The power and voltage level of the power supply is consistent with
the rated voltage of the inverter.
– The input terminals ( R, S, T ) and output terminals ( U, V, W )
are properly connected.
– No short-circuit exists in the peripheral circuit.
– The wiring is secured.
Do install the cover properly before power-on, to prevent the
danger of electric shock !
Do not perform the voltage resistance pressure test on any part of
the inverter, because such test has been done in the factory. Otherwise, it
will cause accidents.
All the peripheral devices must be connected properly under the
instructions in this manual. If not, it may cause an accident !
After power-on:
DANGER
Do not open the cover after power-on, otherwise it may cause
electric shock and damage !
Do not wire or operate the inverter with wet hands, otherwise it
may cause electric shock !
Do not touch any inverter terminals ( including the control
terminals ) , otherwise it may cause electric shock !
At the beginning of power-on, the inverter will carry out safety
testing for external electric circuit automatically. Do not change the
!
CAUTION