A-TS
18
https://a-ts.cn/en/
Table 4-2 DT100 general purpose series
Model
Rated
capacity
( KVA )
Rated output
current ( A )
Applicable motor
power ( KW )
DT100-2S0004G
1.0
2.5
0.4
DT100-2S0007G
1.5
4.0
0.75
DT100-2S0015G
3.0
7.5
1.5
DT100-2S0022G
4.0
10.0
2.2
DT100-4T0007G
1.5
2.3
0.75
DT100-4T0015G
3.0
3.7
1.5
DT100-4T0022G
4.0
5.0
2.2
4.2.2 Ordering information of DT100 series
Please refer to Figure 4-1a and Figure 4-1b.
Series
Power
(KW)
Code
0004
0015
0022
0.4
1.5
2.2
-
4 T 0 0 2 2 G B
DT100
Input
Code
Three Phase T
Single Phase
Voltage Code
220V 2
380V 4
Code Type
Constant
torque
G
-
XX
-
XX
Special machine code:
GM Series changed to default
Design version:0~99
0007
0.75
S
Built - in brake unit
Figure 4-1a DT100 Model Designation
DT100- 4 T0022G
2.2 KW
3PH AC 380-440V 5.8A 50/60HZ
3PH AC 0- 440V 5.0A 0~650HZ
MODEL
:
POWER
:
INPUT
:
OUTPUT
:
S/ N
:
Model
Motor power
Rated input voltage, current and frequency
、
、
Design version
WARNING
* Risk of electric shock
*
*
VS
0000 0219 0000 0000
Barcode
:
Output voltage range rated current and
frequency range
Wait 10mins after power down before removing
the cover
Follow all the instructions in the manual before use
Figure 4-1b DT100 series nameplate