Appendix C: Using a Model 620x in a Model 26-based System
180
• In the
Station Configuration Menu
of the Model 620x programming, the unit must
have its
Communications Mode
set for
Trunked
with the appropriate polarity for
channel grant.
• Set jumper
JP5
(FFSK Output Range) to the “
RAD
” position, if FFSK transmit
levels cannot be set high enough, move it to the “
TEL
” position and try again
Connections to Wire-line
The material shown in the following sub topics is taken from the Model 6 manual.
Basic 2-wire Interface
M6 Connection
Description
J4-pin 7
Ground
J4-pin 8
PTT
J4-pin 9
TX Audio -
J4-pin 11
TX Audio +
J5-pin 1
COR (Channel Grant)
J5-pin 3
RX Audio +
J5-pin 4
RX Audio -
11
9
1
11
9
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
SW-2
SW-1
Primary Model 6
J4
J3
11
9
1
11
9
J4
J3
Secondary Model 6
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
SW-2
SW-1
To a wireline
TX/RX pair
Unit Address = 5
Unit Address = 517
PA Audio ComB
TX & 2W RX Audio & FFSK
TX & 2W RX Audio & FFSK
PA Busy
PA Audio ComA
PA
Basic 2-Wire System
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...