Creating the System Servers
54
CAD Input Selection
Type
This sets the type of CAD license that the translator checks for when the service is
started. Choose from
Serial
,
TriTech_Serial
, or
XML
.
CAD Serial Communications
Port
The CAD Translator uses a serial port when it is supporting the Model 26 Serial
CAD protocol. This field holds the COM port on the FSA Server computer used by
the serial data link coming from the CAD system. It will typically be one of the first
four COM ports on the server machine.
Baud Rate
This is the baud rate used by the CAD-FSA serial connection. It defaults to 9600. It
should be set to whatever speed the connection is using.
FSA Communications
Host
This parameter is for the IP address of the computer running the FSA Server. In
most cases, it will be the same machine that the CAD Translator is running on.
Port
This is the port used by the FSA Server. It defaults to
43001
and should not be
changed.
Note
The default setting is Serial. If you have the XML CAD license, set
this parameter to XML.
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...