Creating the System Servers
56
The window follows all of the usual Windows
®
rules for resizing the window and
scrolling within it. If you wish to clear the existing message history in order to reduce the
clutter of the window, click
Clear Histories
at the right of the center bar.
The hex data displayed in the upper window under the heading
CAD Packet (hex frame
bytes)
can be decoded by referring to the CAD Protocol Document (Zetron part number
027-0059E, included with the purchase of the 930-0117 M26 CAD Interface license). The
direction column (Dir.) should show both transmit (Tx, from FSA Server to CAD) and
receive (Rx, from CAD to FSA Server) traffic. If there is no Rx data present, you should
check the serial port connection between the FSA server computer and the CAD system to
ensure that you have both Tx and Rx connections.
The bottom window shows messages being sent back and forth between the FSA Server
and the FSA CAD Translator (converts XML messages into/out of hex packets used by the
older serial CAD interface.
Note
Unlike the log files, which use the Universal date/time reference,
the Viewer uses the date/time settings of the computer on which
the Viewer is being run.
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...