Using a Model 26 Fire Station Dispatcher for System Backup
140
Programming Changes to the Model 6203
This sub section covers changes that need to be made to the programmable settings in the
station alerting units in order to ensure proper system operation in both normal and backup
operating modes. The settings changed are primarily timers. You should not have to alter
the settings concerning unit type (6203 or 6204) or ID number.
♦
Checking the serial settings for the station alerting units:
1. Connect a compatible serial cable (see
on page 153) between
your computer and socket J1 on the transponder board. (Recommend using Zetron
cable, part number 709-7208.)
2. Set switch SW1-8 to the
ON
position.
3. Using a serial terminal emulation program (such as HyperTerminal), set up a
connection for the COM port to which the cable is connected. The settings should
be: 9600 baud, 8-bit words, 1 stop-bit, no parity checking, and flow control set to
none.
4. Hit the
SPACE
bar three times to open the Model 620x configuration main menu.
5. Enter a “
1
” to open the Station Configuration menu. Confirm the items 1 and 2 are
correctly set.
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...