Appendix A: Details of Model 6203/6204 Hardware
166
Table 11: Switch Settings — Model 620x Transponder Board
Potentiometers
Ten of the audio circuits on the Model 6203 Transponder main board are adjustable. Some
of these circuits must be adjusted before the Model 6203 can transmit and receive
properly. (See
on page
for potentiometer locations.)
For a more detailed procedure for setting the transmit and receive audio levels, see
The Model 6203 and the Model 6204 can produce continuous FFSK test tones, for up to
30 seconds. These test tones are provided to help in the adjustment of the pots associated
Switch
Description
Address Value
SW2 -1
Address bit 1 (LSB)
1
SW2 -2
Address bit 2
2
SW2 -3
Address bit 3
4
SW2 -4
Address bit 4
8
SW2 -5
Address bit 5
16
SW2 -6
Address bit 6
32
SW2 -7
Address bit 7
64
SW2 -8
Address bit 8
128
SW1 -1
Address bit 9
256
SW1 -2
Address bit 10 (MSB)
(0 = Primary Unit at station,
1 = Secondary Unit)
512
SW1 -3
Not Used
—
SW1 -4
Not Used
—
SW1 -5
Not Used
—
SW1 -6
Not Used
—
SW1 -7
Software Configuration Program baud
rate select:
OFF = 1200 baud
ON = 9600 baud
—
SW1 -8
J1 mode selection
OFF = Printer mode
ON = Software Configuration
Program mode
—
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...