137
Model 26 Backup in a Voice over Radio System
5. Leave the laptop attached to the Model 6203 and leave it in the programming mode
for now.
Model 26 FFSK Receive Level
♦
Setting the Model 26 transmit level:
1. Attach an oscilloscope to the
FFSK
test point (TP6) on the back of the Model 26.
The signal to be measured will be approximately 1.0 Vp-p.
2. On the back panel of the Model 26, turn the
4W RCV
pot (R69) fully clockwise
and the
2W RCV
pot (R81) fully counterclockwise.
3. Turn the
FSK POST RCV
pot (R78) fully counterclockwise and set the
VOX
pot
(R31) to its mid-position.
4. At one of the Model 6203 sites that has had its FFSK transmit level set, hit the
SPACE
bar on the computer keyboard three times to open the Model 6203 Main
menu. Then enter an “
8
” to start the
{8} FFSK LEVEL SET
test tone sequence.
5. If the voltage measured at the
FFSK
test point (TP6) while receiving the FFSK test
tone is less than 1Vp-p (0.35 Vrms), turn the
FSK POST RCV
pot (R78) on the
Model 26 clockwise until it is at least 1.0 Vp-p.
6. If the voltage measured at the
FFSK
test point (TP6) while receiving the FFSK test
signal is greater than 1.0 Vp-p (0.35 Vrms), turn the
4W RCV
pot (R69) on the
Model 26 counterclockwise until it is 1.0 Vp-p or less.
Finishing Up
The following list covers the cleaning up after the levels have been set at the Model 26 and
all of the Model 6203 station units.
♦
Finishing up the Model 26 backup system setup:
1. At both the Model 26 location and the Model 6203 site, return the units to normal
operating mode and remove the serial cables.
• Keep entering “e” until you reach the Main menu and then enter “e” one more
time to exit the programming mode.
• Model 6 — move SW1-8 to the off position
• Model 26 — move SW7 to the off position (CAD/Data Logging)
2. Remove all test lead connections and close up the Model 26 and Model 6203 units.
3. After the Model 26 has had a chance to poll all of the Model 6203 units in the
system, try making an alert to each of the units to check whether the voice audio
levels are adequate. If they need to be adjusted use R107 (RCV-4W) on the Model
6203 mother board.
4. In the IP FSA Configuration Utility, under
Global Server Settings
, confirm that
the
Station Retry Timeout
for the IP FSA system is still set to the default setting
of 10.0 seconds.
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...