Operation of the device
000000-1272-175-GA-GB-060613
81
VISULAS YAG III power-up mode
•
When the YAG system is switched on using the key switch (1, Fig. 7), the
system automatically performs a self-test (Fig. 41). Then the Combi mode
is active and the message shown in Fig. 42 is displayed on the YAG
console. The YAG laser can now be operated using the VISULAS Trion
control panel only.
•
The combination message continues to be displayed on the YAG console
as long as the system remains in combination mode and there are no
system errors (Fig. 42).
•
Should an error occur on the VISULAS YAG III whilst in combination
mode, the VISULAS Trion logs off automatically. The relevant error
message is displayed on the YAG console display. The YAG laser cannot
be operated or logged back on until the error has been resolved and the
system restarted.
•
If an error occurs during the system self-test, an error message is
displayed. If the error cannot be eliminated using the troubleshooting
table in the VISULAS Trion user manual, please notify customer service.
Fig. 41
System test