YSI 5200A
243
YSI 5200A
242
continued next page
Menu Maps
Sensor
Setup
DO
(Name)
(Enabled)
DO
(Enabled)
Control
Mode
Set
Point
PID
‐
PWM
PID
‐
4/20mA
Alarms
(Disabled)
5400 only
Probe
Type
Galvanic
5400 only
Membrane
Type
(Teflon
2.0mil)
Display
Format
(mg/l)
mg/l
Sat
mg/l
and
Sat
mg/l
and
Temp
Sat
and
Temp
mg/l,
Sat
and
Temp
Salinity
(0
ppt)
0‐80 ppt
Elevation
(0
Feet)
Run
Screen
→
Menus
→
Sensor
Setup>
DO
(all control modes unless indicated at column 2)
Elevation
(0
Feet)
0‐200X100ft
5400 only
Temp
Source
(User
Defined)
25.0c
User
Defined
OR
AUX
3
AUX
4
AUX
5
AUX
6
Temp
Display
Format
(Celsius)
Fahrenheit
Celsius
Alarm
Low
(3.50
mg/l)
0.0
‐
60.0
mg/l*
Relay
(Disabled)
Alarm
Low
(Disabled)
Instrument
(Instrument)
Device
Address
Local
Machine
Master
Slave
1
‐
31
Relay (Unassigned)
Relay
(Unassigned)
Relay
1
‐
8
Set Point control only
Range
Low
2
(4.00
mg/l)
3.5 ‐ 60.00 mg/l*
Set Point control only
Relay
(Disabled)
Range
Low
2
(Disabled)
Instrument
(Instrument)
Device
Address
Local
Machine
Master
Slave
1
‐
31
Relay
(Unassigned)
Relay
1
‐
8
Set Point control only
Range
Low
(5.00
mg/l)
4.00 ‐ 60 mg/l*
Set Point control only
Relay
(Disabled)
Range
Low
(Disabled)
Instrument
(Instrument)
Device
Address
Local
Machine
Master
Master
Slave
1
‐
31
Relay
(Unassigned)
Relay
1
‐
8
Set
Point
(8.00
mg/l)
5.0‐60.00 mg/l*
PID/PWM
&
PID
‐
4/20mA
only
Control
Up/Down
(Rising)
Rising
Falling
PID/PWM
&
PID
‐
4/20mA
only
PID
Mode
(mg/l)
Sat
mg/l
PID/PWM
&
PID
‐
4/20mA
only
PID
Interval
(100.00
Seconds)
PID/PWM
&
PID
‐
4/20mA
only
PID
Reset
Interval
(20.00
Seconds)
PID/PWM
&
PID
‐
4/20mA
only
PID
Gain
(2.00)
PID/PWM
only
PID
Relay
(Disabled)
DO
(Disabled)
Instrument
(Instrument)
Device
Address
Local
Machine
Continued
from
prior
page
Setup>
DO
(all control modes unless indicated at column 2)
Local
Machine
Master
Slave
1
‐
31
Relay
(Unassigned)
Relay
1
‐
8
PID
‐
4/20mA
only
PID
Output
4/20ma
(Disabled)
DO
(disabled)
Instrument
Channel
Min
(0.0)
Max
(100.0)
Output
Scale
(4.0mA)
Output
Scale
Max
(20.00
mA)
all
menus
must
be
configured
using
AquaManager
Set
Point
control
only
Range
High
(8.50
mg/l)
8.0
to
60.0
mg/l*
Set
Point
control
only
Relay
(Disabled)
Range
High
(Disabled)
Instrument
(Instrument)
Device
Address
Local
Machine
Master
Slave
1
‐
31
Relay
(Unassigned)
Relay
(Unassigned)
Relay
1
‐
8
Set
Point
control
only
Range
High
2
(8.70
mg/l)
8.5
to
60.00
mg/l*
Set
Point
control
only
Relay
(Disabled)
Range
High
2
(Disabled)
Instrument
(Instrument)
Device
Address
Local
Machine
Master
Slave
1
‐
31
Relay
(Unassigned)
Relay
1
‐
8
Alarm
High
(9.00
mg/l)
8.7
to
60.0
mg/l*
Relay
(Disabled)
Alarm
High
(Disabled)
Instrument
(Instrument)
‐
‐
Menu Maps