10-18
IM 704610-01E
10.2 Commands
:DISPlay?
Function
Queries all settings related to the display.
Syntax
:DISPlay?
Example
:DISPLAY?
-> :DISPLAY:MEASURE JITTER
;PARAMETER:JITTER 1;SDEVIATION 1
;AVERAGE 1;CONSTT 1;USNUM 1;LSNUM 1
;EQ 1;DELAY 1;:DISPLAY:SCALE R10
;STAT 1
:DISPlay:MEASure
Function
Switches the statistical value display items or
queries the current setting.
Syntax
:DISPlay:MEASure {JITTer|
SDEViation|AVERage|CONStt|LEVel|
USNum|LSNum|EQ|DELay}
:DISPlay:MEASure?
Example
:DISPLAY:MEASURE JITTER
:DISPLAY:MEASURE?
-> :DISPLAY:MEASURE JITTER
Description • When LVOut:STATe (level measurement) is
OFF, LEVEL cannot be measured.
• Parameters turned OFF using the
DISPlay:PARameter:*** command cannot be
selected.
:DISPlay:PARameter:AVERage
Function
Sets the AVE displayed or queries the current
setting.
Syntax
:DISPlay:PARameter
:AVERage {<Boolean>}
Example
:DISPLAY:PARAMETER:AVERAGE ON
:DISPLAY:PARAMETER:AVERAGE?
-> :DISPLAY:PARAMETER:AVERAGE 1
:DISPlay:PARameter:CONStt
Function
Sets the T display or queries the current setting.
Syntax
:DISPlay:PARameter
:CONStt {<Boolean>}
Example
:DISPLAY:PARAMETER:CONStt ON
:DISPLAY:PARAMETER:CONStt?
-> :DISPLAY:PARAMETER:CONStt 1
:DISPlay:PARameter:DELay
Function
Sets the Dly display or queries the current
setting.
Syntax
:DISPlay:PARameter
:DELay {<Boolean>}
Example
:DISPLAY:PARAMETER:DELAY ON
:DISPLAY:PARAMETER:DELAY?
-> :DISPLAY:PARAMETER:DELAY 1
:DISPlay:PARameter:EQ
Function
Sets the EQ display or queries the current
setting.
Syntax
:DISPlay:PARameter:EQ {<Boolean>}
Example
:DISPLAY:PARAMETER:EQ ON
:DISPLAY:PARAMETER:EQ?
-> :DISPLAY:PARAMETER:EQ 1
:DISPlay:PARameter:JITTer
Function
Sets the
σ
/T display or queries the current
setting.
Syntax
:DISPlay:PARameter
:JITTer {<Boolean>}
Example
:DISPLAY:PARAMETER:JITTER ON
:DISPLAY:PARAMETER:JITTER?
-> :DISPLAY:PARAMETER:JITTER 1
:DISPlay:PARameter:LSNum
Function
Sets the SnL display or queries the current
setting.
Syntax
:DISPlay:PARameter
:LSNum {<Boolean>}
Example
:DISPLAY:PARAMETER:LSNUM ON
:DISPLAY:PARAMETER:LSNUM?
-> :DISPLAY:PARAMETER:LSNUM 1
:DISPlay:PARameter:SDEViation
Function
Sets the
σ
display or queries the current setting.
Syntax
:DISPlay:PARameter
:SDEViation {<Boolean>}
Example
:DISPLAY:PARAMETER:SDEVIAION ON
:DISPLAY:PARAMETER:SDEVIAION?
-> :DISPLAY:PARAMETER:SDEVIAION 1
:DISPlay:PARameter:USNum
Function
Sets the SnU display or queries the current
setting.
Syntax
:DISPlay:PARameter
:USNum {<Boolean>}
Example
:DISPLAY:PARAMETER:USNUM ON
:DISPLAY:PARAMETER:USNUM?
-> :DISPLAY:PARAMETER:USNUM 1
:DISPlay:SCALe
Function
Sets the meter scale or queries the current
setting.
Syntax
:DISPlay:SCALe {R10|R20|SECond}
:DISPlay:SCALe?
Example
:DISPLAY:SCALE R10
:DISPLAY:SCALE?
-> :DISPLAY:SCALE R10