10
10.2 Commands
Command
Function
Page
:SAMPle:ARMing:SOURce
Sets the arming source or queries the current setting.
10-28
:SAMPle:BLOCk?
Queries all settings related to block sampling.
10-28
:SAMPle:BLOCk:SIZE
Sets the number of blocks for block sampling or queries the current setting.
10-28
:SAMPle:BLOCk:STATe
Turns block sampling ON and OFF or queries the current setting.
10-28
:SAMPle:GATE?
Queries all settings related to the gate.
10-28
:SAMPle:GATE:TIME
Sets the gate time or queries the current setting.
10-28
:SAMPle:INHibit?
Queries all settings related to inhibit.
10-28
:SAMPle:INHibit:POLarity
Sets the polarity of inhibit or queries the current setting.
10-29
:SAMPle:INHibit:STATe
Turns ON/OFF inhibit or queries the current setting.
10-29
SSTart Group
:SSTart
Executes single measurement.
10-29
STARt Group
:STARt
Starts the measurement.
10-29
STATus Group
:STATus?
Queries all settings related to the communication status.
10-30
:STATus:CONDition?
Queries contents of the status register.
10-30
:STATus:EESE
Sets the extended event enable register value or queries the current setting.
10-30
:STATus:EESR?
Queries contents of the extended event register, and clears the register.
10-30
:STATus:ERRor?
Queries any error codes that occur and message information.
10-30
:STATus:FILTer
Sets the transition filter or queries the current setting.
10-30
:STATus:QMESsage
Sets whether or not to attach message information to the response to the
“
:STATus:ERRor?
” query or queries the current setting.
10-30
STOP Group
:STOP
Stops the measurement.
10-30
STORe Group
:STORe
Stores setup information.
10-30
SYSTem Group
:SYSTem?
Queries all settings related to system.
10-31
:SYSTem:BRIGhtness:DOTMatrix
Sets the brightness of the dot matrix LED display or queries the current setting.
10-31
UNIT Group
:UNIT?
Queries default units of voltage, time, and frequency.
10-31
:UNIT:TIME
Sets the default unit of time or queries the current setting.
10-31
:UNIT:VOLTage
Sets the default unit of voltage or queries the current setting.
10-31
Common Command Group
*CAL?
Performs calibration and queries the result.
10-32
*CLS
Clears the standard event register, extended event register, and the error queue. 10-32
*ESE
Enters/queries the standard event enable register value.
10-32
*ESR?
Queries the standard event register, and clears the register.
10-32
*IDN?
Queries the instrument type.
10-32
*OPC
Sets whether or not to clear the OPC event upon the completion of the
specified overlap command.
10-32
*OPC?
Creates a response upon the completion of the specified overlap command.
10-33
*OPT?
Queries the installed options.
10-33
*RST
Initializes settings.
10-33
*SRE
Enters/queries the service request enable register value.
10-33
*STB?
Queries the status byte register.
10-33
*TRG
Executes single measurement.
10-33
*TST?
Executes the self test and queries the result.
10-33
*WAI
Holds the subsequent command until the completion of the specified overlap
operation.