< Safety Precautions >
vi
IM 39J06B40-01EN
14th Edition: May 30, 2022
*12: “X” indicates specific condition of use, in a hazardous area of Zone 2, install DTSXL System in a lockable metal cabinet which
meets the IP54 or higher protection rating provided in IEC 60529.
*13: The EAC mark is as follows.
*14: Refer to each suffix code for DTSX3000, DTOS2L, DTOS4L and DTOS16L.
*15: Including the confirmation of 10 restricted substances defined in the Commission Delegated Directive (EU) 2015/863
amending Annex II to Directive 2011/65/EU.
SEE ALSO
- For details on the power supply modules (NFPW426, NFPW441, NFPW442, and NFPW444) and
CPU module (NFCP050), see General Specifications of the STRADOM FCN/FCJ (GS 34P02Q12-
01E, GS 34P02Q13-01E) and the STARDOM FCN/FCJ Installation Guide (TI 34P02Q91-01E).
- For safety precautions on use of power equipment, see Chapter A3, “Power Supply Equipment.”
- For details on selection and wiring of power cables, see Section A5.1, “Power Supply Wiring.
●
Installation conditions
When installing the device, the installation requirements of the device must be satisfied.
Install the device under the following conditions:
Item
Specifications
Power Supply
Power
supply
Module
Rating
NFPW426
12 V DC
(
3.4 A
)
24 V DC
(
1.7 A
)
NFPW441
100
~
120 V AC
(
1.4 A
)、
50/60 Hz
NFPW442
220
~
240 V AC
(
0.7 A
)、
50/60 Hz
NFPW444
24 V DC
(
3.3 A
)
Ambient Temperature (Operation)
-40
~
65
°C
(*1)
Ambient humidity (Operation)
20 to 80% RH (no condensation)
Installation height
Altitude up to 3000 m (*2)
Installation category based on IEC 61010
*3
Ⅰ
、
Ⅱ
Pollution degree based on IEC 61010
*4
2
Installation
Indoor use only
*1:
0 to 55
℃
when power supply module NFPW441, NFPW442, or NFPW444 is used.
*2:
Altitude up to 2000 m when power supply module NFPW441, NFPW442 or NFPW444 is used.
*3:
Installation category is the specification of the impulse withstanding voltage which is termed overvoltage category.
Category I applies to specially protected electrical devices on the secondary side (when NFPW444 / NFPW426 is
used.) Category II applies to electrical devices (when NFPW441 / NFPW442 is used)
*4:
Pollution degree represents the level of foreign matter adhesion, solid, liquid, and gaseous, which may decrease the
withstanding voltage.
Pollution degree 2 is applicable to general indoor atmosphere.
●
Installation method
Follow the guidance below on how to use this device to guarantee satisfactory safety
and performance.
- Keep the cabinet door of the device closed.
- Confirm that all the empty slots in the cabinet are covered by dummy covers.
- Confirm that all cables are firmly secured with the screws.
- Install rack type devices in the cabinet and lock the cabinet doors for safety.
- Prepare a dedicated circuit breaker in the same room of the device so that it can be
used to cut off the power supply when abnormality occurs. Use this breaker to
shutdown power supply to equipment devices when a device abnormality occurs.
Use a breaker that meets STARDOM power supply specification requirements.
Summary of Contents for DTSXL
Page 2: ...Blank Page...
Page 15: ...Copyright and Trademark Notices xiii IM 39J06B40 01EN 14th Edition May 30 2022 Blank Page...
Page 23: ...IM 39J06B40 01EN 14th Edition May 30 2022 Blank Page...
Page 83: ...IM 39J06B40 01EN 14th Edition May 30 2022 Blank Page...
Page 215: ...PART B Software B 132 IM 39J06B40 01EN 14th Edition May 30 2022...
Page 222: ...PART B Software B 139 IM 39J06B40 01EN 14th Edition May 30 2022...
Page 233: ...PART B Software B 150 IM 39J06B40 01EN 14th Edition May 30 2022...
Page 239: ...PART B Software B 156 IM 39J06B40 01EN 14th Edition May 30 2022...
Page 247: ...PART B Software B 164 IM 39J06B40 01EN 14th Edition May 30 2022...
Page 253: ...IM 39J06B40 01EN 14th Edition May 30 2022 Blank Page...
Page 289: ...IM 39J06B40 01EN 14th Edition May 30 2022 Blank Page...