Administrator’s Guide for Yealink VC800&VC500 Video Conferencing System
180
Parameter
Description
Configuration Method
Noise Reduction
(2D)
Specifies the noise reduction (2D)
mode.
Off
Low
Middle
High
Default:
Middle
Remote Control
Web User Interface
Noise Reduction
(3D)
Specifies the noise reduction (3D)
mode.
Valid Values:
0-22
Default:
3
Remote Control
Web User Interface
WDR
Specifies the wide dynamic range.
Off-do not use WDR
1-5
Default:
2
Remote Control
Web User Interface
Hangup Mode
Enables or disables the camera to
flip the image view when camera is
handed at up-side-down position
Default:
Off
Web User Interface
Camera Pan
Direction
Configures the pan direction of the
camera.
Normal
Reversed
Default:
Normal
If the camera reversed mode is
enabled, the camera pan direction
will be reversed when pressing the
left and right navigation keys on the
remote control. In this case, you can
set the camera pan direction to
Reversed.
Web User Interface
Reset Camera
Reset the camera settings to factory
defaults.
Note:
The camera presets will also
be cleared.
Web User Interface
Summary of Contents for MeetingSpace VC500
Page 1: ......
Page 4: ......
Page 10: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System x ...
Page 16: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System xvi ...
Page 24: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System 8 ...
Page 28: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System 12 ...
Page 210: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System 194 ...
Page 228: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System 212 ...
Page 252: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System 236 ...
Page 258: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System 242 ...
Page 276: ...Administrator s Guide for Yealink VC800 VC500 Video Conferencing System 260 ...