1
LEDs
2
flap with labeling strip
3
contact bar
4
flap opened with inner label
CAUTION!
Please regard that the voltage applied to an output channel must be
£
the
voltage supply applied to L+. Due to the parallel connection of in- and
output channel per group, a set output channel may be supplied via an
applied input signal. Thus, a set output remains active even at power-off
of the voltage supply with the applied input signal. Non-observance may
cause module demolition.
Structure
VIPA System 300S
Digital Input/Output Modules
323-1BH01 - DI 8xDC 24V, DO 8xDC 24V 1A
HB140 | SM-DIO | | en | Rev. 16-43
76