![YASKAWA SGLFW User Manual Download Page 45](http://html.mh-extra.com/html/yaskawa/sglfw/sglfw_user-manual_3223785045.webp)
2.6 Selecting Peripheral Devices
2-13
2
2.6.4 Regenerative Resistors
* 1. For the optional JUSP-RA05 Regenerative Resistor Unit.
* 2. For the optional JUSP-RA18 Regenerative Resistor Unit.
Note: 1. If the SERVOPACK cannot process the regenerative power, an external regenerative resistor is
required. Refer to
6.8.5 External Regenerative Resistor
,
6.8.6 Regenerative Resistor
, and
7.6
Connecting Regenerative Resistors
.
2. The following table shows the manufacturers of each device.
Main Circuit
Power Supply
SERVOPACK Model
Regenerative Resistor
(Refer to 6.8.5, 6.8.6, and 7.6.)
Capacity
(kW)
SGDH-
Built-in
Externally
connected
Resistance
(
Ω
)
Capacity
(W)
Single-phase
200 V
0.05
A5AE
−
−
−
0.10
01AE
0.20
02AE
0.40
04AE
Three-phase
200 V
0.45
05AE
50
60
−
0.75
08AE
1.0
10AE
1.5
15AE
30
70
2.0
20AE
25
140
3.0
30AE
12.5
140
5.0
50AE
8
280
7.5
75AE
(3.13)
∗
1
(1760)
∗
1
JUSP-RA05
Three-phase
400 V
0.45
05DE
108
70
−
1.0
10DE
1.5
15DE
2.0
20DE
45
140
3.0
30DE
5.0
50DE
32
180
(18)
∗
2
(880)
∗
2
JUSP-RA18
7.5
75DE
Peripheral Device
Manufacturer
External Regenerative Resistor
Iwaki Wireless Research Institute
External Regenerative Unit
Yaskawa Electric Corporation
Summary of Contents for SGLFW
Page 270: ...9 3 9...