![YASKAWA SGLFW User Manual Download Page 425](http://html.mh-extra.com/html/yaskawa/sglfw/sglfw_user-manual_3223785425.webp)
12.4 List of Parameters
12-27
12
* 1. The setting range for the software version 32 or later
* 2. Available only for the software version 32 or later
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Reference
Section
Pn100
Speed Loop Gain
1 to 2000
1 Hz
40
Immedi-
ately
10.3.4
Pn101
Speed Loop Integral Time Constant
15 to 51200
0.01 ms
2000
Immedi-
ately
10.3.5
Pn102
Position Loop Gain
1 to 2000
1/s
40
Immedi-
ately
10.3.3
Pn103
Mass Ratio
0 to 10000
(0 to 20000)
∗
1
1%
0
Immedi-
ately
9.2.2
9.2.3
10.2.6
Pn104
2nd Speed Loop Gain
1 to 2000
1 Hz
40
Immedi-
ately
10.4.9
Pn105
2nd Speed Loop Integral Time Constant
15 to 51200
0.01 ms
20.00
Immedi-
ately
10.4.9
Pn106
2nd Position Loop Gain
1 to 2000
1/s
40
Immedi-
ately
10.4.9
Pn108
Bias Width Addition
0 to 250
1 reference
unit
7
Immedi-
ately
10.4.6
Pn109
Feed-forward
0 to 100
1%
0
Immedi-
ately
10.4.1
Pn10A
Feed-forward Filter Time Constant
0 to 6400
0.01 ms
0
Immedi-
ately
10.4.1
Pn10B
Gain-related Application Switches
−
−
0000
After
restart /
Immedi-
ately
−
Pn10C
Mode Switch Force Reference
0 to 800
1%
200
Immedi-
ately
10.4.5
0
1
2
3
4
0
1
0
1
2
3
Use
internal force reference
as the condition. (Level setting:
Pn10C
)
Use
speed reference
as the condition. (Level setting:
Pn181
)
Use
acceleration
as the condition. (Level setting:
Pn182
)
Use
position error pulse
as the condition. (Level setting:
Pn10F
)
No
mode switch function
available
PI control
I-P control
No automatic gain switching available
Position reference
Position error
Both position reference and position error
Mode Switch Selection
(Refer to
10.4.5
Using
the
Mode
Switch
(P/PI
Switching.))
Setting
Validation
Setting
Validation
Speed Loop Control Method
(Refer to
10.3.5
Speed
Loop
Integral
Time
Constant.
Reserved (Do not change)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Immediately
After restart
After restart
Automatic Gain Switching Selection
(Refer to
10.4.11
)
∗
2
Setting
Validation
∗
2
Summary of Contents for SGLFW
Page 270: ...9 3 9...