12.4 List of Parameters
12-37
12
Pn50E
Output Signal Selection 1
−
−
3211
After
restart
−
Pn50F
Output Signal Selection 2
−
−
0000
After
restart
−
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Reference
Section
0
1
2
3
0 to 3
Disabled (the above signal is not used.)
Outputs the signal from CN1-25, -26 output terminal.
Outputs the signal from CN1-27, -28 output terminal.
Outputs the signal from CN1-29, -30 output terminal.
Same as /COIN
Same as /COIN
Same as /COIN
Positioning Completion Signal Mapping (/COIN)
(Refer to
9.8.5
Positioning
Completed
Output
Signal
.)
Speed Coincidence Detection Signal Mapping (/V-CMP)
(Refer to
9.7.8
Speed
Coincidence
Output.
)
Movement Detection Signal Mapping (/TGON)
(Refer
to
9.13.3)
Servo Ready Signal Mapping (/S-RDY)
(Refer to 9.13.4 Servo Ready (/S-RDY) Output.)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0 to 3
0 to 3
0
1
2
3
0 to 3
Disabled (the above signal is not used.)
Outputs the signal from CN1-25, -26 output terminal.
Outputs the signal from CN1-27, -28 output terminal.
Outputs the signal from CN1-29, -30 output terminal.
Same as /CLT
Same as /CLT
Same as /CLT
Force Limit Detection Signal Mapping (/CLT)
(Refer to
9.11.5
Checking
Output
Force
Limiting
during
Operation
.)
Speed Limit Detection Signal Mapping (/VLT)
(Refer to
9.9.4
Limiting
Linear
Servomotor
Speed
during
Force
Control
.)
Brake Interlock Signal Mapping (/BK)
(Refer to
8.3.3
Setting
for
Holding
Brakes
.)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0 to 3
0 to 3
Warning Signal Mapping (/WARN)
(Refer to
9.13.2
Warning
Output
(/WARN)
.)
Summary of Contents for SGLFW
Page 270: ...9 3 9...