8 Digital Operator/Panel Operator
8.3.3 Output Circuit Signal Allocation
8-28
8.3.3 Output Circuit Signal Allocation
Functions can be allocated to the following sequence output signals. After having changed the parameter, turn
OFF the power and ON again to enable the parameters.
means factory setting.
* This function is valid for the software version 32 or later.
CN1 Pin No.
25/(26)
27/(28)
29/(30)
Remark
Parameter Setting
Allocation
Pn512=n.xxx
Pn512=n.xx
x
Pn512=n.x
xx
0
1
0
1
0
1
Positioning
Completion
(/COIN)
Pn50E.0 = n.xxx
0
Invalid
L:
Valid output signal: Low level
H:
Valid output signal: High level
Invalid:
Do not use the output signal.
Factory Setting
Note:
The output signals for Positioning
Completion Signal and Speed Coinci-
dence Detection Signal differ depend-
ing on the control method.
1
L
H
2
L
H
3
L
H
Speed Coinci-
dence Detection
(/V-CMP)
Pn50E.1 = n.xx
x
0
Invalid
1
L
H
2
L
H
3
L
H
Movement Detec-
tion
(/TGON)
Pn50E.2 = n.x
xx
0
Invalid
1
L
H
2
L
H
3
L
H
Servo Ready
(/S-RDY)
Pn50E.3 = n.
xxx
0
Invalid
1
L
H
2
L
H
3
L
H
Force Limit
Detection
(/CLT)
Pn50F.0 = n.xxx
0
Invalid
1
L
H
2
L
H
3
L
H
Speed Limit
Detection
(/VLT)
Pn50F.1 = n.xx
x
0
Invalid
1
L
H
2
L
H
3
L
H
Brake
(/BK)
Pn50F.2 = n.x
xx
0
Invalid
1
L
H
2
L
H
3
L
H
Warning
(/WARN)
Pn50F.3 = n.
xxx
0
Invalid
1
L
H
2
L
H
3
L
H
Near
(/NEAR)
Pn510.0 = n.xxx
0
Invalid
1
L
H
2
L
H
3
L
H
Reference Pulse
Input Multiplication
(/PSELA)*
Pn510.2 = n.x
xx
0
Invalid
1
L
H
2
L
H
3
L
H
Pn512:
Pn510:
Pn50F:
Pn50E:
Summary of Contents for SGLFW