![YASKAWA SGLFW User Manual Download Page 219](http://html.mh-extra.com/html/yaskawa/sglfw/sglfw_user-manual_3223785219.webp)
7.4 Examples of I/O Signal Connections
7-29
7
(2) Sequence Input Circuit Interface
CN1 connector terminals 40 to 47 is explained below.
The sequence input circuit interface connects through a relay or open-collector transistor circuit. Select a low-
current relay otherwise a faulty contact will result.
Note: The 24 VDC external power supply capacity must be 50 mA minimum.
(3) Sink Circuit and Source Circuit
The SERVOPACK’s I/O circuit uses a bidirectional photocoupler. Select either the sink circuit or the source cir-
cuit according to the specifications required for each machine.
(4) Output Circuit Interface
There are three types of SERVOPACK output circuits:
(a) Line-driver Output Circuit
CN1 connector terminals, 33-34: phase-A signal, 35-36: phase-B signal and 19-20: phase-C signal are
explained below.
Encoder serial data converted to two-phase (phases A and B) pulse output signals (PAO, /PAO, PBO, /PBO)
and zero-point pulse signals (PCO, /PCO) are output via line-driver output circuits. Normally, the
SERVOPACK uses this output circuit in speed control to comprise the position control system at the host
controller. Connect the line-driver output circuit through a line receiver circuit at the host controller.
Relay Circuit Example
Open-collector Circuit Example
3.3 k
Ω
/S-ON, etc.
SERVOPACK
24 VDC
+24VIN
+24VIN 3.3 k
Ω
/S-ON, etc.
SERVOPACK
24 VDC
Sink Circuit
Source Circuit
24 V
I/O power
supply
SERVOPACK input
+
−
SERVOPACK input
+
−
24 V
I/O power
supply
Summary of Contents for SGLFW
Page 270: ...9 3 9...