![YASKAWA SGLFW User Manual Download Page 441](http://html.mh-extra.com/html/yaskawa/sglfw/sglfw_user-manual_3223785441.webp)
12.5 Parameter Recording Table
12-43
12
Pn481
40 Hz
Polarity Detection Speed Loop Gain
Imme-
diately
Pn482
30.00 ms
Polarity Detection Speed Loop Integral
Time Constant
Imme-
diately
Pn483
30 %
Forward Force Limit
Imme-
diately
Pn484
30 %
Reverse Force Limit
Imme-
diately
Pn500
7
Position Completion Width
Imme-
diately
Pn504
7
Near Signal Width
Imme-
diately
Pn505
262144
Overflow Level
Pn506
0 ms
Brake Reference - Servo OFF Delay Time
Imme-
diately
Pn508
500 ms
Servo OFF - Brake Reference Waiting
Time
Imme-
diately
Pn509
20 ms
Momentary Hold Time
Imme-
diately
Pn50A
2100
Input Signal Selection 1
After
restart
Pn50B
6543
Input Signal Selection 2
After
restart
Pn50C
8888
Input Signal Selection 3
After
restart
Pn50D
8888
Input Signal Selection 4
After
restart
Pn50E
3211
Output Signal Selection 1
After
restart
Pn50F
0000
Output Signal Selection 2
After
restart
Pn510
0000
Output Signal Selection 3
After
restart
Pn512
0000
Output Signal Reverse Settings
After
restart
Pn513
8888
Input Signal Selection 5
After
restart
Pn51E
0%
Excessive Position Error Warning Level
Imme-
diately
Pn580
10 mm/s
Zero Clamp Level
Imme-
diately
Pn581
20 mm/s
Zero Speed Level
Imme-
diately
Pn582
10 mm/s
Speed Coincidence Signal Output Width
Imme-
diately
Pn583
100mm/s
Brake Reference Output Speed Level
Imme-
diately
Pn584
0%
/max. speed
Motor Self-cooling Ratio
Imme-
diately
Pn600
0 W
External Regenrative Resistor Capacity
Imme-
diately
Parame-
ter
Factory
Setting
Name
Setting
Valida-
tion
Summary of Contents for SGLFW
Page 270: ...9 3 9...