EAS00756
STARTING CIRCUIT CUTOFF SYSTEM
OPERATION
If the engine stop switch is set to “
” and the
main switch is set to “ON” (both switches are
closed), the starter motor can only operate if at
least one of the following conditions is met:
• The transmission is in neutral (the neutral
switch is closed).
• The clutch lever is pulled to the handlebar
(the clutch switch is closed) and the side-
stand is up (the sidestand switch is closed).
The starting circuit cutoff relay prevents the
starter motor from operating when neither of
these conditions has been met. In this
instance, the starting circuit cutoff relay is open
so current cannot reach the starter motor.
When at least one of the above conditions has
been met the starting circuit cutoff relay is
closed and the engine can be started by press-
ing the starter switch.
WHEN THE TRANSMISSION IS
IN NEUTRAL
WHEN THE SIDESTAND IS UP
AND THE CLUTCH LEVER IS
PULLED TO THE HANDLEBAR
1
Battery
2
Main fuse
3
Main switch
4
Ignition fuse
5
Engine stop switch
6
Starting circuit cutoff relay
7
Diode assembly
8
Clutch switch
9
Sidestand switch
0
Neutral switch
A
Start switch
B
Starter relay
C
Starter motor
Summary of Contents for VMX12 2001
Page 1: ...VMX12 2001 3LRD AE1 SERVICEMANUAL ...
Page 2: ......
Page 8: ......
Page 9: ...GEN INFO 1 ...
Page 11: ...GEN INFO ...
Page 21: ......
Page 22: ...SPEC 2 ...
Page 24: ...SPEC ...
Page 52: ...2 28 SPEC OIL FLOW DIAGRAMS 1 Camshaft 2 Main gallery 3 Crankshaft 4 Oil level switch ...
Page 54: ...2 30 SPEC OIL FLOW DIAGRAMS 1 Crankshaft 2 Oil pipe 3 Oil filter ...
Page 65: ...CHK ADJ 3 ...
Page 125: ......
Page 126: ...ENG 4 ...
Page 130: ...ENG ...
Page 236: ......
Page 237: ...COOL 5 ...
Page 239: ...COOL ...
Page 258: ...CARB 6 ...
Page 260: ...CARB ...
Page 272: ......
Page 273: ...CHAS 7 ...
Page 389: ......
Page 390: ...ELEC 8 ...
Page 396: ...8 4 ELEC SWITCHES ...
Page 417: ...8 25 ELEC STARTER MOTOR 3 Install O rings 1 bolts 2 New T R 5 Nm 0 5 m kg ...
Page 445: ...TRBL SHTG 9 ...