MTi 1-series User Manual
Xsens MTi User Manual Repository
Hardware Integration Manual
Copyright © 2021 Xsens
Page 82
External components single supply (I
2
C interface)
Power supply specifications
The table below shows the maximum operating voltage ratings of the MTi 1-series. Exposure to
any voltage beyond maximum operating voltage rating condition for extended periods may
affect device reliability and lifetime.
Maximum operating voltage ratings
Min
Max
Unit
VDDA
2.8
3.6[1]
V
VDDA
ripple
50
mVpp
VDDIO
2.8
VDDA +
0.1
V
[1] Previous generation version ≤1.1, VDDA max: 3.45V