MTi 1-series User Manual
Xsens MTi User Manual Repository
Datasheet
Copyright © 2021 Xsens
Page 44
Min
Max
Unit
Comments
Operating
temperature
-40
+85
ºC
VDDA
0.3
4.0
V
With respect to GND
VDDIO
0.3
VDDA +
0.5
V
With respect to GND
SYNC_IN
5
V
With respect to GND
Acceleration
#3
10,000
g
Any axis, unpowered, for
0.2 ms
ESD protection
#4
±2000
V
Human body model
[3]
This is a mechanical shock (g) sensitive device. Proper handling is required to prevent
damage to the part.
[4]
This is an ESD-sensitive device. Proper handling is required to prevent damage to the
part.