![background image](http://html2.mh-extra.com/html/xerox/phaser-6121mfp/phaser-6121mfp_service-manual_4154850116.webp)
3-10
Phaser 6121MFP Service Manual
Error Messages and Codes
0022
Owing to noise interference on the line, receiving side can not receive
correct data within specified time (no ECM).
0023
Received PWD error in RSD or upgrade F/W.
0024
TX and RX machine have different machine IDs in upgrade F/W.
0025
TX and RX machine have different company IDs in upgrade F/W.
0026
Remote monitor level error, remote side can not access in upgrade F/W.
0027
Remote monitoring prohibited.
002A
Line problem.
0030
Cannot receive any signal within 6 seconds at phase D.
0031
Received incorrect signal at phase D (not EOP, MPS, EOM, DCS PPS_Q,
PPS_Q, etc.).
0032
Carrier signal not received within 6 seconds after sending MCF or RTP,
RTN signal.
0033
Received DCN signal at phase D within pages (not last page).
0039
In non-ECM mode, data received but the next line data not received
within 13.1 seconds.
003F
Remote side TSI not defined in machine one touch or speed dial
directory.
0040
Carrier signal not received within 6 seconds after sending CTR.
0041
Carrier signal not received within 6 seconds after sending PPR.
0042
Correct signal not received after sending RNR signal.
0043
Received incorrect signal at phase D in ECM mode.
0044
Carrier /FSK signal not received within 6 seconds after sending MCF in
ECM mode.
0045
Correct signals not received after sending RNR response with ERR signal.
0046
Received incorrect signal after sending RNR (Receiver Not Ready).
0047
Correct signal not received after sending ERR signal.
0048
Correct signal not received after receiving PPS_PRI_Q, PRI_Q, or
EOR_PRI_Q.
0049
Correct signal not received within 13 seconds after sending PIP/PIN
signal.
004A
Line energy over threshold last 60 seconds after MCF, and can not detect
FSK or carrier signal in ECM mode.
004B
Cannot detect correct FSK signal even though detected FSK tone within 6
seconds.
004C
Handshake failure during re-train or between page in V.34 RX.
004E
Received DCN signal after sending DIS in V.34.
004F
Remote side disconnected after sending ANSam in V.8 phase.
0050
Correct signal not received after sending CJ signal in V.8 phase.
0051
Phase 3 signal not received within 20 seconds after phase 2 in V.34.
Code
Description
Summary of Contents for PHASER 6121MFP
Page 1: ...Phaser 6121MFP Multi Function Printer Phaser 6121MFP Service Manual...
Page 2: ......
Page 12: ...x Phaser 6121MFP Service Manual Contents...
Page 22: ...xx Phaser 6121MFP Service Manual...
Page 42: ...1 20 Phaser 6121MFP Service Manual General Information...
Page 106: ...2 64 Phaser 6121MFP Service Manual Theory of Operation...
Page 109: ...Phaser 6121MFP Service Manual 3 3 Error Messages and Codes s6121mfp 372...
Page 194: ...3 88 Phaser 6121MFP Service Manual Error Messages and Codes...
Page 306: ...6 44 Phaser 6121MFP Service Manual Adjustments and Calibrations...
Page 405: ...Phaser 6121MFP Service Manual 8 85 Service Parts Disassembly 3 Remove the spring s6121mfp 255...
Page 432: ...8 112 Phaser 6121MFP Service Manual Service Parts Disassembly...
Page 437: ...Phaser 6121MFP Service Manual 9 5 Parts List...
Page 477: ...Phaser 6121MFP Service Manual 9 45 Parts List...
Page 488: ...9 56 Phaser 6121MFP Service Manual Parts List...
Page 489: ...10 Chapter Wiring In this chapter Plug Jack Designations and Locator Diagrams Wiring Diagrams...
Page 530: ...1 6 Phaser 6121MFP Service Manual Index...
Page 531: ......