WIM-PD-002_B
Page
26
of
38
7.1
Maintenance schedule
•
Initial oil replacement is recommended after the first 300 hours of operation.
•
Replace oil every 1000 working hours or six months whichever comes first.
•
Check magnetic plug during every oil change for any evidence of metal shavings and grease bushings
in heads with Klüber paste ALTEMP Q NB 50, or equal.
•
Check oil level every 300 hours.
•
Confirm PPD main shaft
endplay
every 1000 hours.
Endplay on main shaft must be between 0.012-0.020 in [0.3-0.5mm].
Summary of Contents for WPD-02
Page 1: ...Power Pump Drive Installation Maintenance Manual Model WPD 02...
Page 31: ...WIM PD 002_B Page 31 of 38 9 2 Z Side input with extensions with WP3 02 003 pump...
Page 32: ...WIM PD 002_B Page 32 of 38 9 3 Z Side input without extensions with WP3 02 002 pump...
Page 33: ...WIM PD 002_B Page 33 of 38 9 4 Y Side Output with extensions with WP3 02 002 pump...
Page 37: ...WIM PD 002_B Page 37 of 38 This Page Intentionally left Blank...