MAINTENANCE
Safety Devices Inspection (CE Version Only)
4
4-20
25doc063022
MAINTENANCE
2. Inspection of the control circuits with the E-STOP button pressed
Start the engine;
Turn the tensioner handle to engage the blade;
Press the E-STOP button located on the left side of the control box. The engine should be
stopped.
With E-STOP button pressed try to move the saw head up and down (using switch and Set-
works buttons) and forward/backward using power feed switch. Both systems should not
start.
With E-STOP button pressed try to start the debarker blade motor and move the debarker
arm in and out. The debarker should not work.
With E-STOP button pressed try to move the blade guide arm in and out. The blade guide
arm should not work.
20_121d
Emergency
Stop Button
Engine Key
Switch
Saw Head
Forward
Saw Head
Reverse
Saw Head
Up
Saw Head
Down
Debarker
Arm In/Out
Debarker
Motor On/Off
Blade Guide
Arm In/Out