8 2 1 6 9 7 :
A M P1 -1 6 V S e r i e s U s e r G u i d e
© 2 0 1 3 Wo h l e r Te c h no lo g i e s , I n c . A l l r i g h t s r e s e r ved .
115
A p p e nd i x 9
Establishing Connectivity
Co n ne c t i n g t o a L A N
Figure 9–1
NetBurner IPSetup Dialog - Unconfigured
4.
If multiple NetBurner modules appear in the
Select a Unit
box, be
sure to note which IP address belongs to the AMP1-16V you wish to
update.
Setting a Static Ethernet Configuration
1.
An IP address of
0.0.0.0
means the Netburner is using DHCP
addressing, and the network will give the module its address (as it has in
the example in
above:
192.168.0.7).
When using a direct
connection, you must use a static Ethernet configuration. In some
fixed installations and networks, it may also be desirable to have a
static Ethernet configuration in the unit. If you desire to use a static
Ethernet configuration AND connect to a LAN, you MUST first
obtain an address and mask from your network administrator.
Failure to do so may result in intermittent problems throughout
your network.
2.
For our example, we’ll be using the address
192.168.0.2
with the
network mask of
255.255.255.0
. Simply type the IP address into the
IP
field and the network mask into the
Network Mask
field. The
GateWay and DNS addresses are not used by the AMP1-16V, and
may be left set to 0.0.0.0.
Decision Point:
If you wish to use the DHCP address provided by the LAN, the AMP1-
16V is now connected and you are finished with this procedure.
Otherwise, if you wish to set a static IP address instead, continue on to the
next section.