CAUTION:
Prior to applying final torque to screws in Step 16, verify solenoid wires are not
pinched between nut plate and vent assembly. This could create a shorted
circuit causing potential equipment damage and/or personal injury.
16. Place vent block on vent tube. Line up nut plate behind vent assembly and replace the four
(4) screws securing block to vent tube and vent assembly.
17. Drop vent ball (if applicable) down through waffle onto vent block.
18. Place weight down in weight lifter.
19. Place vent back onto vent assembly.
20. Replace the 14 screws securing back panels and Danger Label panel to rear of fryer.
21. Place muffler onto fryer and place unit back into service.
REPLACE WEIGHT
(ITEM NO. 38)
Tools:
N/A
Procedure:
1.
DANGER :
Turn off electrical power and disconnect electrical power supply. If unit is
CAUTION:
Utilize care when removing muffler in Step 2. Muffler may contain very hot
water.
2. Remove muffler and place in sink.
3. Lift and remove vent back.
4. Remove defective weight from weight lifter.
5. Insert new weight into weight lifter.
6. Place vent back onto
vent
assembly.
7. Place muffler onto fryer and place unit back into service.
REPLACE HINGE BLOCK (REAR)
(ITEM NO. 29)
Tools:
Phillips Screwdriver #2; Slotted Screwdriver; Box End Wrench - 9/I6”; Open
1.
DANGER:
Turn
off electrical power and disconnect electrical power supply. If unit is
Procedure
WINSTON
49
LIT.6710/REV.0/9-91
hardwired,
CIRCUIT BREAKER MUST BE OFF.
End Wrench - 1-3/16”; Putty Knife; Hammer; Gloves.
hardwired, CIRCUIT BREAKER MUST BE OFF.