22. Replace the four (4) screws securing escutcheon to relay panel.
23. Replace the two (2) screws securing eyebrow to relay panel and place unit back into service.
REPLACE Hi LIMIT THERMOSTAT
(ITEM N0. 54)
Tools:
Phillips Screwdriver #2; Slotted Screwdriver; Open End Wrench - 9/16”.
Procedure:
1.
DANGER:
Turn off electrical power, disconnect electrical power supply, dram shortening
and allow to cool. If unit is hardwired,
CIRCUIT BREAKER MUST BE OFF.
2. Remove the two (2) screws securing eyebrow to relay panel and save for reuse.
CAUTION:
Utilize care in preventing escutcheon from falling forward when removing
3.
4.
5.
screws in Step 3.
Remove the four (4) screws securing escutcheon to relay panel and save for reuse. Lower
escutcheon slowly until secure in open position.
Remove screw securing locking arm to thermostat
shaft. Save screw and arm for reuse.
Disconnect probe assembly from extension wire
(See Figure 6 on following page).
CAUTION:
Utilize care in preventing relay
6.
7.
8.
9.
10.
11.
12.
panel from falling forward when
removing screws in
Step 5.
Remove the four (4) screws securing relay
panel to side panels and save for reuse.
Lower panel slowly until secure
(See Figure 4).
Rotate insulation strap gaining access to
buckle. Remove insulation strap and save
for reuse.
Remove section of insulation gaining access
to thermostat bulb and compression nut.
Remove
lid gaining access to inside of
cooking vessel.
Remove screw securing thermostat bulb
and clamp to top heater coil and save for reuse.
Note position of bulb and clamp to ensure
proper installation of new thermostat
(See Figure 5).
Remove compression nut securing
thermostat bulb to bushing.
Remove bushing and bulb from
inside of cooking vessel.
FIG. 4
FIG. 5
WINSTON
31
LIT.6710/REV.0/9-91