CAUTION:
Utilize care to prevent relay panel
from falling unsupported when
removing screws in Step 5.
5. Remove the four (4) screws securing relay
panel to side panels and save for reuse.
Lower panel slowly until secure (See Figure 7).
6. Pull down top edge of insulation and remove
compression nut securing probe assembly to
cooking vessel (See Figure 8).
7. Remove lid gaining access to inside of cooking
vessel.
8. Using rubber mallet, gently tap probe allowing
ferrule to unseat from bushing on outside of
cooking vessel.
9. Remove bushing securing probe assembly to
cooking vessel.
flush against probe bushing prior to Step 10.
10. Insert new probe into hole and secure bushing to
cooking vessel using 11/16” open end wrench.
11. Apply silicone sealant to ferrule.
12.
CAUTION:
Position of probe tip is critical.
Align probe tip to where bend in probe occurs
at 3/8" from fryer wall. Tighten compression
nut using 9/16” open end wrench securing
probe in place. (See Figure 9).
13. Replace the four (4) screws securing
relay panel to side panels.
14. Connect probe wires to extension
wires.
15. Replace the four (4) screws securing
escutcheon to relay panel.
16. Replace the two (2) screws securing
_
eyebrow to relay
panel and place unit
back into service.
FIG. 7
FIG. 9
FIG. 8
WINSTON
33
LIT.6710/REV.0/9-91
NOTE:
Verify aluminum washer is seated