1.
DANGER:
Turn off
electrical power, disconnect
electrical power supply, drain shortening
and allow to cool. If unit is hardwired
CIRCUIT BREAKER MUST BE OFF.
2. Remove the two (2) screws securing eyebrow
to relay panel and save for reuse.
3.
4.
14. Replace the two (2) screws securing new thermostat to relay panel.
NOTE:
Verify aluminum washer is in place. Washer should be placed flush against
bushing prior to Step 14.
15. Route thermostat bulb through cooking vessel and heater holder. Replace screw securing
bulb and clamp to top heater coil.
16. Apply a
small
amount of silicone sealant to bushing and secure to cooking vessel.
17. From inside of cooking vessel, holding thermostat bulb secure at point of entrance, tighten
compression nut.
18. Replace insulation and strap.
19. Replace the four (4) screws securing relay panel to side panels.
20. Slide locking arm over thermostat shaft and replace screw securing arm to relay panel.
21. Replace the four (4) screws securing escutcheon to relay panel.
22. Replace the two (2) screws securing eyebrow to relay panel and place unit back into
service.
REPLACE PROBE
(ITEM NO. 36)
Tools:
Phillips Screwdriver #2; Wrench - 9/16”; Wrench - 11/16”; Rubber Mallet; Silicone
Sealant.
Procedures:
CAUTION:
Utilize care in preventing
escutcheon from falling forward
when removing screws in Step 3.
Remove the four (4) screws securing
escutcheon to relay panel and save for
reuse. Lower escutcheon slowly until
secure in open position.
Disconnect probe assembly from
extension wires (See Figure 6).
13. Remove the two (2) screws securing thermostat to relay panel and save for reuse.
FIG. 6
WINSTON
32
LIT.6710/REV.0/9-91