REPLACE WEIGHT LIFTER
(ITEM NO. 61)
Tools:
Slotted Screwdriver; Phillips Screwdriver #2; Needle Nose Pliers.
Procedure:
1.
DANGER:
Turn off electrical power and disconnect electrical power supply. If unit is
hardwired,
CIRCUIT BREAKER MUST BE OFF.
CAUTION:
Utilize care when removing muffler in Step 2. Muffler may contain very hot
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
water.
Remove muffler and place in sink.
Lift and remove vent back and save for reuse.
Remove weight and save for reuse.
Remove the seven (7) screws securing Danger Label panel and back panel on either left
or right hand side (servicer preference) and save for reuse. Remove back panel.
Disconnect the two (2) vent solenoid wires
from harness wires at insulated terminals
(See Figure 21).
Remove the four (4) screws securing
vent block and ball (if applicable) to vent
assembly. Save screws, block and ball (if
applicable) for reuse.
NOTE:
Some 4-Head and 6-Head
models utilize a stainless steel
vent ball (located on vent block) with
weight to regulate pressure.
Remove vent tube O-ring.
Remove the four (4) screws securing vent
assembly to rear of fryer and save for reuse.
Remove vent assembly.
Remove.vent spring and save for reuse
Remove vent solenoid cotter pin and save
for reuse.
Remove defective weight lifter assembly.
With teflon slide in place and weight
lifter in upright position, insert weight
lifter arm through slot in vent assembly.
Insert cotter pin through solenoid and
weight lifter arm. Secure
cotter
pin in
place by bending (See Figure 22).