Watlow EZ-ZONE
®
RMC Module
•
140
•
Chapter 6 Factory Page
RMC Module • Factory Page
Display
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data
Type
& Read/
Write
[CUSt]
[FCty]
Custom Setup Menu
[`par]
[ Par]
Custom Menu
Parameter 1 to 20
Select the parameters
that will appear in the
Home Page.
The Parameter 1 value
will appear in the
upper display of the
Home Page. It cannot
be changed with the
Up and Down Keys in
the Home Page.
The Parameter 2 value
will appear in the
lower display in the
Home Page. It can be
changed with the Up
and Down Keys, if the
parameter is a writ-
able one.
Scroll through the other
Home Page parame-
ters with the Advance
Key
‰
.
nonE]
None
[`l;st]
Limit Status
[`L;hy]
Limit Hysteresis
[`Lh;S]
Limit High Set Point
[`LL;S]
Limit Low Set Point
[gSd1]
Guaranteed Soak Devia-
tion 1 Value
[gSd2]
Guaranteed Soak Devia-
tion 2 Value
[P;ACr]
Profile Action Request
[P;Str]
Profile Start
[idLE]
Idle Set Point
[t;tUn]
TRU-TUNE+
®
Enable
[`r;rt]
Ramp Rate
[`C;hy]
Cool Hysteresis
[`C;Pb]
Cool Proportional Band
[`h;hy]
Heat Hysteresis
[`h;Pb]
Heat Proportional Band
[``db]
Dead Band
[``td]
Time Derivative
[``ti]
Time Integral
[`C;Pr]
Cool Power
[`h;Pr]
Heat Power
[`C;M]
User Control Mode
[`AUt]
Autotune
[``op]
Open Loop Set Point
[AC;SP]
Active Set Point
[AC;pu]
Active Process Value
[StPt]
Set Point
CUSt]
Custom Menu
[`A;hy]
Alarm Hysteresis
[`A;hi]
Alarm High Set Point
[`A;Lo]
Alarm Low Set Point
[USr;r]
User Restore Set
[`C_F]
Display Units
[`i;CA]
Input Calibration Offset
[`Pro]
Process
- - - -
- - - -
- - - -
- - - -
14005
uint
RWES
[`iid]
iid]
Custom Setup (1 to 20)
Instance ID
Select the instance of
the parameter selected
above to be displayed.
1 to 4
- - - -
- - - -
- - - -
- - - -
14003
uint
RWES
Note:
Some values will be rounded off to fit in the four-character display . Full values can be read
with another interface .
If there is only one instance of a menu, no submenus will appear .
R: Read
W: Write
E: EE-
PROM
S: User
Set