Watlow EZ-ZONE
®
RMC Module
•
111
•
Chapter 4 Setup Page
RMC Module • Setup Page
Dis-
play
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data
Type
& Read/
Write
[gLbL]
[`Set]
Global Menu
[`C_F]
[ C_F]
Global
Display Units
Select which scale to use
for temperature.
[```F]
°F (30)
[```C]
°C (15)
°F
43348
- - - -
- - - -
3005
- - - -
[AC;LF]
[AC.LF]
Global
AC Line Frequency
Set the frequency to the
applied ac line power
source.
[``50]
50 Hz (3)
[``60]
60 Hz (4)
60 Hz
1026
0x6A
(106)
1
4
- - - -
6004
uint
RWES
[d;prs]
[dPrS]
Global
Display Pairs
Defines the number of
Display Pairs.
1 to 10
1
- - - -
0x6A
(103)
1
0x1C (28)
- - - -
3028
uint
RWES
[USr;S]
[USr.S]
Global
User Settings Save
Save all of this control-
ler's settings to the
selected set that have a
Data Type of RWES
[SEt1]
User Set 1 (101)
[SEt2]
User Set 2 (102)
[none]
None (61)
None
26
0x(101)
1
0xE (14)
118
1014
uint
RWE
[USr;r]
[USr.r]
Global
User Settings Restore
Replace all of this con-
troller's settings with
another set.
[FCty]
Factory (31)
[none]
None (61)
[SEt1]
User Set 1 (101)
[SEt2]
User Set 2 (102)
None
24
0x65
(101)
1
0xD (13)
117
1013
uint
RWE
[`PRo]
[`Set]
Profile Menu
[R;typ]
[R.tyP]
Profile
Ramping Type
Use to have the ramp-
ing set point change at
a set Rate or over a set
interval of Time as pro-
file steps.
[rate]
Rate (81)
[``ti]
Time (143)
Time
5354
0x7A
(122)
1
0x26 (38)
- - - -
22038
uint
RWE
[P;typ]
[P.tyP]
Profile
Profile Type
Set the profile startup to
be based on a set point
or a process value.
[StPt]
Set Point (85)
[`Pro]
Process (75)
Set Point
5294
0x7A
(122)
1
8
- - - -
22008
uint
RWE
[`GSE]
[ gSE]
Profile
Guaranteed Soak En-
able
Enables the guaranteed
soak deviation function
in profiles.
[`oFF]
Off (62)
[``on]
On (63)
Off
5290
0x7A
(122)
1
6
- - - -
22006
uint
RWE
Note:
Some values will be rounded off to fit in the four-character display .
Full values can be read with other interfaces .
Note:
If there is only one instance of a menu, no submenus will appear .
** These parameters/prompts are available in these menus with firmware revisions 6 .0 and
above .
R: Read
W: Write
E:
EEPROM
S:
User Set