Watlow EZ-ZONE
®
RMC Module
•
134
•
Chapter 5 Profiling Page
RMC Module •
Profile Page
Display
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data Type
& Read/
Write
[Ent1]
[Ent1]
Subroutine Step (1 to
150)
Event 1
Select whether output
programmed as Pro-
file Event Out A is on,
unchanged or off dur-
ing this step.
[Ucgd]
Unchanged (1557)
[`oFF]
Off (62)
[``on]
On (63)
Un-
changed
30466
[offset 86]
0x69
(105)
1 to (150)
0xE (14)
- - - -
5014
uint
RWE
[Ent2]
[Ent2]
Subroutine Step (1 to
150)
Event 2
Select whether output
programmed as Pro-
file Event Out B is on,
unchanged or off dur-
ing this step.
[Ucgd]
Unchanged (1557)
[`oFF]
Off (62)
[``on]
On (63)
Un-
changed
30468
[offset 86]
0x69
(105)
1 to (150)
0xF (15)
- - - -
5015
uint
RWE
[Ent3]
[Ent3]
Subroutine Step (1 to
150)
Event 3
Select whether output
programmed as Pro-
file Event Out C is on,
unchanged or off dur-
ing this step.
[Ucgd]
Unchanged (1557)
[`oFF]
Off (62)
[``on]
On (63)
Un-
changed
30470
[offset 86]
0x69
(105)
1 to (150)
0x10 (16)
- - - -
5016
uint
RWE
[Ent4]
[Ent4]
Subroutine Step (1 to
150)
Event 4
Select whether output
programmed as Pro-
file Event Out D is on,
unchanged or off dur-
ing this step.
[Ucgd]
Unchanged (1557)
[`oFF]
Off (62)
[``on]
On (63)
Un-
changed
30472
[offset 86]
0x69
(105)
1 to (150)
0x11 (17)
- - - -
5017
uint
RWE
[Ent5]
[Ent5]
Subroutine Step (1 to
150)
Event 5
Select whether output
programmed as Pro-
file Event Out E is on,
unchanged or off dur-
ing this step.
[Ucgd]
Unchanged (1557)
[`oFF]
Off (62)
[``on]
On (63)
Un-
changed
30474
[offset 86]
0x69
(105)
1 to (150)
0x12 (18)
- - - -
5018
uint
RWE
[Ent6]
[Ent6]
Subroutine Step (1 to
150)
Event 6
Select whether output
programmed as Pro-
file Event Out F is on,
unchanged or off dur-
ing this step.
[Ucgd]
Unchanged (1557)
[`oFF]
Off (62)
[``on]
On (63)
Un-
changed
30476
[offset 86]
0x69
(105)
1 to (150)
0x13 (19)
- - - -
5019
uint
RWE
[Ent7]
[Ent7]
Subroutine Step (1 to
150)
Event 7
Select whether output
programmed as Pro-
file Event Out G is on,
unchanged or off dur-
ing this step.
[Ucgd]
Unchanged (1557)
[`oFF]
Off (62)
[``on]
On (63)
Un-
changed
30478
[offset 86]
0x69
(105)
1 to (150)
0x14 (20)
- - - -
5020
uint
RWE
Note: Some values will be rounded off to fit in the four-character display . Full values
can be read with other interfaces .
If there is only one instance of a menu, no submenus will appear .
R: Read
W: Write
E: EEPROM
S: User Set