50°C
100°C
Design temperature
100 cSt
1000 cSt
Viscosity for dimensioning electric motor
6.3.4.4
Separator pre-heater (1E01)
The pre-heater is dimensioned according to the feed pump capacity and a given settling tank
temperature.
The surface temperature in the heater must not be too high in order to avoid cracking of the
fuel. The temperature control must be able to maintain the fuel temperature within ± 2°C.
Recommended fuel temperature after the heater depends on the viscosity, but it is typically
98°C for HFO and 20...40°C for MDF. The optimum operating temperature is defined by the
sperarator manufacturer.
The required minimum capacity of the heater is:
where:
heater capacity [kW]
P =
capacity of the separator feed pump [l/h]
Q =
temperature rise in heater [°C]
Δ
T =
For heavy fuels
Δ
T = 48°C can be used, i.e. a settling tank temperature of 50°C. Fuels having
a viscosity higher than 5 cSt at 50°C require pre-heating before the separator.
The heaters to be provided with safety valves and drain pipes to a leakage tank (so that the
possible leakage can be detected).
6.3.4.5
Separator (1S01/1S02)
Based on a separation time of 23 or 23.5 h/day, the service throughput Q [l/h] of the separator
can be estimated with the formula:
where:
max. continuous rating of the diesel engine(s) [kW]
P =
specific fuel consu 15% safety margin [g/kWh]
b =
density of the fuel [kg/m
3
]
ρ
=
daily separating time for self cleaning separator [h] (usually = 23 h or 23.5 h)
t =
The flow rates recommended for the separator and the grade of fuel must not be exceeded.
The lower the flow rate the better the separation efficiency.
Sample valves must be placed before and after the separator.
6-16
DAAB605814
Wärtsilä 46F Product Guide
6. Fuel Oil System
Summary of Contents for 46F Series
Page 1: ...Wärtsilä 46F PRODUCT GUIDE ...
Page 4: ...This page intentionally left blank ...
Page 8: ...This page intentionally left blank ...
Page 18: ...This page intentionally left blank ...
Page 86: ...This page intentionally left blank ...
Page 104: ...This page intentionally left blank ...
Page 154: ...This page intentionally left blank ...
Page 162: ...This page intentionally left blank ...
Page 170: ...This page intentionally left blank ...
Page 176: ...This page intentionally left blank ...
Page 194: ...This page intentionally left blank ...
Page 200: ...This page intentionally left blank ...
Page 202: ...This page intentionally left blank ...
Page 207: ...Fig 21 7 List of symbols DAAF406507 7 DAAB605814 21 5 21 ANNEX Wärtsilä 46F Product Guide ...